summaryrefslogtreecommitdiff
path: root/KiCAD/rev04_16.sch-bak
diff options
context:
space:
mode:
authorPavel V. Shatov (Meister) <meisterpaul1@yandex.ru>2020-09-23 15:21:46 +0300
committerPavel V. Shatov (Meister) <meisterpaul1@yandex.ru>2020-09-23 15:21:46 +0300
commita0a00256b970d0c60171ca9a97dbfbd95e4e0c7d (patch)
tree45e627e605476a3b9d82fdf6a67fed1f13c5e97e /KiCAD/rev04_16.sch-bak
parent6eb45a988c9dc9c7a5835aa9cb820c97795b1f85 (diff)
Renamed schematics sheets for consistency.
Diffstat (limited to 'KiCAD/rev04_16.sch-bak')
-rw-r--r--KiCAD/rev04_16.sch-bak228
1 files changed, 228 insertions, 0 deletions
diff --git a/KiCAD/rev04_16.sch-bak b/KiCAD/rev04_16.sch-bak
new file mode 100644
index 0000000..a10ade4
--- /dev/null
+++ b/KiCAD/rev04_16.sch-bak
@@ -0,0 +1,228 @@
+EESchema Schematic File Version 4
+EELAYER 30 0
+EELAYER END
+$Descr B 17000 11000
+encoding utf-8
+Sheet 17 27
+Title "rev04_16"
+Date "15 10 2016"
+Rev ""
+Comp ""
+Comment1 ""
+Comment2 ""
+Comment3 ""
+Comment4 ""
+$EndDescr
+Text Notes 3050 3000 0 60 ~ 12
+*) Middle Right Bank
+Text Notes 6350 2900 0 60 ~ 12
+*) Upper Left Bank
+Text Notes 3950 3700 0 60 ~ 12
+*) Completely unused banks\nstill must be powered
+Text Notes 7450 3600 0 60 ~ 12
+*) Completely unused banks\nstill must be powered
+Text Notes 7900 1030 0 84 ~ 17
+FPGA unused banks
+$Comp
+L Cryptech_Alpha:VCCO_3V3 #VCCO_3V3_031
+U 1 1 58023F33
+P 3850 3200
+F 0 "#VCCO_3V3_031" H 3850 3200 20 0000 C CNN
+F 1 "+VCCO_3V3" H 3850 3130 30 0000 C CNN
+F 2 "" H 3850 3200 70 0000 C CNN
+F 3 "" H 3850 3200 70 0000 C CNN
+ 1 3850 3200
+ 1 0 0 -1
+$EndComp
+$Comp
+L Cryptech_Alpha:VCCO_3V3 #VCCO_3V3_032
+U 1 1 58023F32
+P 7350 3100
+F 0 "#VCCO_3V3_032" H 7350 3100 20 0000 C CNN
+F 1 "+VCCO_3V3" H 7350 3030 30 0000 C CNN
+F 2 "" H 7350 3100 70 0000 C CNN
+F 3 "" H 7350 3100 70 0000 C CNN
+ 1 7350 3100
+ 1 0 0 -1
+$EndComp
+Wire Wire Line
+ 3850 3400 3650 3400
+Wire Wire Line
+ 3850 3400 3850 3500
+Wire Wire Line
+ 3850 3500 3850 3600
+Wire Wire Line
+ 3850 3600 3850 3700
+Wire Wire Line
+ 3850 3700 3650 3700
+Wire Wire Line
+ 3850 3600 3650 3600
+Wire Wire Line
+ 3850 3500 3650 3500
+Wire Wire Line
+ 3850 3200 3850 3400
+Wire Wire Line
+ 3850 3900 3650 3900
+Wire Wire Line
+ 3850 3800 3850 3900
+Wire Wire Line
+ 3850 3700 3850 3800
+Wire Wire Line
+ 3850 3800 3650 3800
+Wire Wire Line
+ 7350 3300 7150 3300
+Wire Wire Line
+ 7350 3300 7350 3400
+Wire Wire Line
+ 7350 3400 7350 3500
+Wire Wire Line
+ 7350 3500 7350 3600
+Wire Wire Line
+ 7350 3600 7150 3600
+Wire Wire Line
+ 7350 3500 7150 3500
+Wire Wire Line
+ 7350 3400 7150 3400
+Wire Wire Line
+ 7350 3100 7350 3300
+Wire Wire Line
+ 7350 3800 7150 3800
+Wire Wire Line
+ 7350 3700 7350 3800
+Wire Wire Line
+ 7350 3600 7350 3700
+Wire Wire Line
+ 7350 3700 7150 3700
+$Comp
+L Cryptech_Alpha:XC7A200TFBG484_NEW U13
+U 4 1 58023F31
+P 3450 6100
+F 0 "U13" H 3040 3090 60 0000 L BNN
+F 1 "~" H 3450 6100 50 0001 C CNN
+F 2 "Cryptech_Alpha_Footprints:BGA484C100P22X22_2300X2300X254" H 3040 3090 60 0001 C CNN
+F 3 "" H 3450 6100 50 0001 C CNN
+ 4 3450 6100
+ 1 0 0 -1
+$EndComp
+$Comp
+L Cryptech_Alpha:XC7A200TFBG484_NEW U13
+U 7 1 58023F30
+P 6950 6000
+F 0 "U13" H 6540 2990 60 0000 L BNN
+F 1 "~" H 6950 6000 50 0001 C CNN
+F 2 "Cryptech_Alpha_Footprints:BGA484C100P22X22_2300X2300X254" H 6540 2990 60 0001 C CNN
+F 3 "" H 6950 6000 50 0001 C CNN
+ 7 6950 6000
+ 1 0 0 -1
+$EndComp
+NoConn ~ 3650 4000
+NoConn ~ 3650 4100
+NoConn ~ 3650 4200
+NoConn ~ 3650 4300
+NoConn ~ 3650 4400
+NoConn ~ 3650 4500
+NoConn ~ 3650 4600
+NoConn ~ 3650 4700
+NoConn ~ 3650 4800
+NoConn ~ 3650 4900
+NoConn ~ 3650 5000
+NoConn ~ 3650 5100
+NoConn ~ 3650 5200
+NoConn ~ 3650 5300
+NoConn ~ 3650 5400
+NoConn ~ 3650 5600
+NoConn ~ 3650 5500
+NoConn ~ 3650 5700
+NoConn ~ 3650 5800
+NoConn ~ 3650 5900
+NoConn ~ 3650 6000
+NoConn ~ 3650 6200
+NoConn ~ 3650 6100
+NoConn ~ 3650 6300
+NoConn ~ 3650 6400
+NoConn ~ 3650 6500
+NoConn ~ 3650 6600
+NoConn ~ 3650 6700
+NoConn ~ 3650 6800
+NoConn ~ 3650 6900
+NoConn ~ 3650 7000
+NoConn ~ 3650 7100
+NoConn ~ 3650 7200
+NoConn ~ 7150 3900
+NoConn ~ 7150 4000
+NoConn ~ 7150 4100
+NoConn ~ 7150 4200
+NoConn ~ 7150 4300
+NoConn ~ 7150 4400
+NoConn ~ 7150 4500
+NoConn ~ 7150 4600
+NoConn ~ 7150 4700
+NoConn ~ 7150 4800
+NoConn ~ 7150 4900
+NoConn ~ 7150 5000
+NoConn ~ 7150 5100
+NoConn ~ 7150 5200
+NoConn ~ 7150 5300
+NoConn ~ 7150 5400
+NoConn ~ 7150 5500
+NoConn ~ 7150 5600
+NoConn ~ 7150 5700
+NoConn ~ 7150 5800
+NoConn ~ 7150 5900
+NoConn ~ 7150 6000
+NoConn ~ 7150 6100
+NoConn ~ 7150 6300
+NoConn ~ 7150 6200
+NoConn ~ 7150 6400
+NoConn ~ 7150 6600
+NoConn ~ 7150 6500
+NoConn ~ 7150 6800
+NoConn ~ 7150 6700
+NoConn ~ 7150 6900
+NoConn ~ 7150 7000
+NoConn ~ 7150 7100
+NoConn ~ 7150 7200
+NoConn ~ 7150 7300
+NoConn ~ 7150 7400
+NoConn ~ 7150 7500
+NoConn ~ 7150 7700
+NoConn ~ 7150 7600
+NoConn ~ 7150 7800
+NoConn ~ 7150 7900
+NoConn ~ 7150 8000
+NoConn ~ 7150 8100
+NoConn ~ 7150 8200
+NoConn ~ 7150 8300
+NoConn ~ 7150 8400
+NoConn ~ 7150 8500
+NoConn ~ 7150 8700
+NoConn ~ 7150 8800
+NoConn ~ 7150 8600
+NoConn ~ 3650 7300
+NoConn ~ 3650 7400
+NoConn ~ 3650 7500
+NoConn ~ 3650 7600
+NoConn ~ 3650 7700
+NoConn ~ 3650 7800
+NoConn ~ 3650 7900
+NoConn ~ 3650 8200
+NoConn ~ 3650 8000
+NoConn ~ 3650 8100
+NoConn ~ 3650 8300
+NoConn ~ 3650 8400
+NoConn ~ 3650 8500
+NoConn ~ 3650 8600
+NoConn ~ 3650 8700
+NoConn ~ 3650 8800
+NoConn ~ 3650 8900
+Connection ~ 3850 3400
+Connection ~ 3850 3500
+Connection ~ 3850 3600
+Connection ~ 3850 3700
+Connection ~ 3850 3800
+Connection ~ 7350 3300
+Connection ~ 7350 3400
+Connection ~ 7350 3500
+Connection ~ 7350 3600
+Connection ~ 7350 3700
+$EndSCHEMATC